Looking For A Trane Replacement Coil

If you need Trane replacement coil within a Trane system, but aren’t sure about the dimensions or decoding the model #, send this to Capital Coil & Air for pricing. On most Trane AHU’s, the AHU model #, as well as the coil or “part #”, is listed as “Service Model No Coil”. If you […]
Steam Distributing Coils (Non-Freeze)

Were you aware that Steam Distributing coils or “Non-Freeze” steam coils were essentially discovered by accident? At the inception of the HVAC industry, steam coils were originally designed to be shorter in length because there was not a good way to evacuate condensate. In an effort to make steam coils longer in length, the concept of a steam coil containing a tube within a tube was invented.
Top 5 Reasons Commercial HVAC Coils Prematurely Fail

Capital Coil & Air has come across virtually every scenario over the years in which a commercial HVAC coil had to be prematurely replaced, and we have since created an easy guide targeting the main reasons HVAC Coils prematurely fail.
Different Types of Steam Coils

There are two types of steam coils: standard steam coil, which is used in most reheat applications, and steam distributing coils, which are used in applications where the entering air temperature is below 40 F degrees.
Chilled Water Coils – Circuiting Made Easy

Circuiting chilled water coils is really a balancing act of tube velocity and pressure drop. In other words, think of a coil as a matrix. Each coil has a specific number of rows, and a specific number of tubes within each row.
Frozen Steam Coils: How Do You Prevent This?

Freezes generally happen in older systems, however if your new system is not maintained properly or correctly installed, your steam coil can and will freeze.
Top 10 Fan Coil FAQ’s

1. A fan coil is among the easiest units to understand in the HVAC industry. Basically, there is a small forward curved fan, a coil, and sometimes a filter. They are all direct drive units. Click HERE to see Capital Coil’s full Fan Coil Product Lineup. 2. Fan coils run from 200 CFM to 2200 CFM, […]
Top 10 Chilled Water Coil Facts

Every Chilled Water Coil selection is about balance. Your coil selection balances the rows/fins versus the cost of the coil pressure drops/performance. Trying to cut corners on your initial selection may save you money upfront, but you will inevitably pay it back down the line through added energy costs. This is a truism for every manufactured […]
OEM Replacement Coils: Repair or Replace

The real reason why OEM HVAC coils need to be replaced rather than repaired is due to energy costs. If your coil is not operating near desired levels, you’ll need to increase the energy to make it work at its peak performance.
Now Offering R-454B Refrigerant for All DX Coils

In keeping with most of the OEM’s in 2024, Capital Coil is helping everyone transition from R-410A over to R-454B refrigerant in their DX Coils. Whether you are designing a new system, or retrofitting an existing one with a condensing system, Capital Coil can help in making the switch in refrigerants.