What Does “Splitting” DX (Evaporator) Coils Mean

***Now Offering R-454B Refrigerant for All DX Coils

“Splitting” DX (Evaporator) coils is one of the toughest concepts to understand in the coil business. “Splitting” the coil simply means that (2) or more compressors can operate off of the same coil. One obvious advantage, or reason that you might “split” DX (Evaporator) coils is that you can shut down (1) of the compressors when the cooling load does not require it. This in turn saves energy, which saves $ when the cooling load is not operating at maximum design conditions. For example, let’s use a coil that is designed to give you (40) tons, but the coil is split so that (2) 20-ton compressors are feeding the same coil. If you only require ½ of the maximum load on any given day, you can shut down (1) compressor completely and operate the other one at 100%. This is a money-saving feature that you need to be aware of if you deal with DX coils on a regular basis. This requires special circuiting arrangements, and this is where the confusion starts with most folks. There are three primary ways to deal with this:DX (Evaporator) Coils

FACE SPLIT

Splitting the coil is nothing more than putting (2) completely separate fin/tube packs (coils) into one common casing. When you hear the term “face-splitting” a coil, you are drawing a horizontal line from left to right across the face of the coil and dividing the coil into a top and bottom half. It is like having two separate coils in one casing in that each half is circuited by itself. You hook up (1) compressor for the top half, and (1) compressor for the bottom.

In practice, this configuration is no longer used with much frequency because this arrangement leads to air being directed across the entire face of the coil. This disadvantage is especially apparent when only one half of the coil is in use because you’ll need a complicated damper/duct system to ensure that air is only directed to that portion of the coil in operation.

Row Split

“Row splitting” a coil is dividing the coil by drawing a line vertically and putting some portion of the total rows in (1) circuit, while putting the remaining rows in the other circuit. With this configuration, the air passes across the entire face of the coil, and will always pass across the rows that are in operation.

Please be aware that this configuration also comes with certain issues in that this kind of split makes it very hard to achieve a true 50/50 split. Let’s use an (8) row coil as an example. You would like to “row split” this coil with (4) rows/circuit, which would appear to be a perfect 50/50 split. The problem here is that the first (4) rows, located closest to the entering air, pick up a much higher portion of the load than the last (4) rows. In actuality, this coil’s split is closer to 66% / 34%, which will not match the 50/50 compressors. Another option is try to split the coil between (3) & (5) rows. While not 50/50 either, this configuration is closer. However, a new challenge arises because you have now created a coil that is very difficult to build and correctly circuit. In short, you need almost perfect conditions along with a degree of luck to achieve a true 50/50 split using this method.

Intertwined Circuiting

The most common to split coils today is to “intertwine” the circuiting. This means that every alternate tube in the coil is included in (1) circuit, while the other tubes are included in the (2nd) circuit. For example, tubes 1, 3,5,7,9, etc. in the first row are combined with tubes 2, 4, 6,8,10, etc. in the second row. The same tubes in succeeding rows form (1) circuit. You are essentially including every alternate tube in the entire coil into (1) circuit, which (1) compressor will operate. All of the remaining tubes not included in the first circuit will now encompass the second circuit.

The advantage of this configuration is that the air passes across the entire face of the coil, and, if one of the compressors is on, there are always tubes in operation. Every split is now exactly 50/50 because it cannot be any other way. Most DX coils are now configured in this manner due to these advantages.

Capital Coil has been, and will remain, the most reliable source for all commercial and OEM replacement coils. Our #1 job is to make to your job easier, so please reach out. You will be glad you did.

 

RELATED POSTS

CHILLED WATER, DX (EXPANSION) COILS & MOISTURE CARRYOVER

Now Offering R-454B Refrigerant for All DX Coils

DX & Chilled Water Cabinet Coils

CATEGORY SUCCESS

Now Offering R-454B Refrigerant for All DX Coils

In keeping with most of the OEM’s in 2024, Capital Coil is helping everyone transition from R-410A over to R-454B refrigerant in their DX Coils. Whether you are designing a new system, or retrofitting an existing one with a condensing system, Capital Coil can help in making the switch in refrigerants.DX Coils

If you are not yet aware, the EPA is working hand in hand with many of the major OEM’s to help reduce commercial HVAC’s carbon footprint. One of the major ways in which HVAC manufacturers are helping and complying with the new industry standards is the gradual change in refrigerants from R-410A to R-454B. Beginning in January of 2025, no new system is allowed to be built or imported using the older refrigerants. Without going into a deep dive on the differences, R-454B offers a lower GWP (global warming potential) alternative to R-410A. Hence the mandate to change to that refrigerant type. 

However, Capital Coil will still offer R-22 and R-410A for DX Coils in older systems that might not be compatible with R-454B. In other words, Capital Coil has been, and will remain, the most reliable source for all commercial and OEM replacement coils. Our #1 job is to make to your job easier, so please reach out. You will be glad you did.

RELATED POSTS

What Does “Splitting” A DX (Evaporator) Coil Mean?

Condenser Coils Failing? Here’s probably why….

OEM Replacement Coils: Repair or Replace

CATEGORY SUCCESS

Direct Expansion & Chilled Water Cabinet Coils

There are lots of ducted cooling applications with chilled water and/or DX (Evaporator) coils where you need to add incremental cooling to an existing system. However, there is an important difference when using heating coils. Because it’s a Cabinet Coilheating coil, there is no humidification occurring or water/condensate to draw. Due to these factors, cooling coils require a little more creativity and labor to install.

At Capital Coil & Air, we have removed all of the guesswork out of the application. Capital Coil manufactures Custom Coil Cabinet sections from as small as 12” x 12” sections to as large as 54” x 90” sections. We manufacture these units in both Chilled Water and DX (Expansion), as well as in 1/2” & 5/8” copper tube coils. You have the option to select anything from (3) rows to (8) rows. Additionally, we will custom-design the Cabinet around whichever site you select. Cabinet units include both insulation & drain pans, while the supports and casing allow you to connect directly to the ductwork. We can also add a Heating Coil inside the unit for more dehumidification if needed. Cabinet Coils are perfect for either heavy or light-duty installations.

All Cabinet Coils are available on Capital Coil’s Quick-Ship Program as well. As you are probably all-too-familiar, trying to custom design coils in the field is a pain. Using Cabinet Coils will greatly ease the whole installation process. Please see our Insulated Cabinet Coil Brochure for more details on available custom sizes.

Capital Coil & Air looks forward to the chance to your coil replacement specialists. Please give us a try on your next project!

RELATED POSTS

Chilled Water Coils & Moisture Carryover

New Product Offering: Insulated Cabinet Coils

Top 10 Chilled Water Coil Facts

CATEGORY SUCCESS

Quick, Reliable & Uncommonly Fast

 Quick, Reliable & Uncommonly Fast

You have many choices when buying replacement coils and choosing a coil supplier. You could decide to diversify and work with numerous suppliers, based on a particular need. However, Capital Coil & Air can make your buying decisions a lot easier. We have been in the coil business for many years, and in this industry, we recognize what is important vs. what is irrelevant. That translates into us having good insight on what you need and how best to support you as a customer.

Quick

Coils today typically do not have much “preventative” maintenance done on them. Most everybody just waits until a coil fails and then worries about the problem at that time. And when coils inevitably fail, they fail during the times when you need them most; i.e. cooling coils failing in the summer and hot water coils breaking down in the winter. As a result, there is usually an urgency attached to most HVAC projects. Generally speaking, most jobs require some form of “quick-ship”. Capital Coil & Air gives you (4) different shipping options for all replacement coils. Our standard ship time is 3 – 4 weeks, but if you need your order faster, Capital Coil will accommodate that need. We do not want to have a “one and done” transaction. Capital Coil’s goal as a business is to have a customer base that we work with for 20 years, not 20 minutes. While we will do our best to give you the fairest price possible, you have to recognize that there is an additional premium associated with quick-shipments on replacement coils. However, you will never pay that premium if Capital Coil is late on manufacturing your order. We’ve built our business on quick-ships, and we hit 99% of all deadlines on orders the last two years. In other words, we rarely miss! We give you options, and you only pay for what you really need.

Reliability

Reliability encompasses so many things in the coil industry. For example, if you need a price today, and the sales rep takes (2) days to get back to you, that’s unacceptable and unreliable. If you require a drawing to help you design a job, and you are waiting for a week to have it returned? Again, not what Capital Coil considers reliable. If a coil supplier promises you a ship date and ships (2) weeks late? Once again, not reliable. Do any of the above issues sound familiar? It is easy to make extravagant promises, and companies do it all of the time. However, Capital Coil’s success rate on meeting and exceeding shipping schedules says more than any promise we can make. We believe in under-promising and over-delivering, not the reverse!

  • Capital Coil responds quickly to all inquiries for pricing, general information, and engineering assistance
  • Capital Coil manufactures high quality equipment in the U.S.A. and is AHRI Certified
  • Capital Coil’s years of experience will help you quickly pick the correct product for the correct application
  • Capital Coil provides accurate shipping dates, real-time tracking and common carrier information after your order has left our factory

We do all of the above to make everything in your life easier. Capital Coil holds itself to the highest standards for both reliability and customer service. In short, we want your experience with us to be professional and simple. Please call or email our sales department for any job – no matter how large or small. We greatly look forward to the opportunity to work with you on your next project.

RELATED POSTS

Your Commercial HVAC Replacement Experts-Why Work With US?

Customers are a business top priority. So why is customer service such a challenge?

Large enough to service all of your replacement coil needs, but small enough to care about what you think

CATEGORY SUCCESS

Does Your HVAC Coil Selection Program Leave You With More Questions Than Answers?

At Capital Coil & Air, we have an accurate and user-friendly coil selection program to select and choose coils. Of course, making good selections is based on having years of experience working with coils of all types and sizes, and Coil Selection Programwe at Capital Coil have that necessary expertise.

When designing a coil, the object is to balance cost and performance together, and that is one area in which we can greatly assist. We do not always choose the cheapest coil because the cheapest coil in almost never the best coil. There are always pressure drops, materials of construction, performance requirements and a host of other things that all play into good or bad coil selections. These are even more relevant in the coil replacement market!

The object is not to duplicate a problem with a coil, but to instead solve the problem and make the coil perform better and last longer. This requires problem solving and making selections that are not always “in the box”.

Part of any successful selection process is having a good selection program to help you. But what makes a program good? First and foremost, you must get the correct results, or you have bad information that is also useless. But apart from that, the selection program must be easy to navigate through. There are “red lights” and “stop signs” built into the program to keep you from making bad selections. Our selection program has most, if not all, coil configurations and styles that you’re likely to run across. We are confident that you’ll find the selection program user-friendly, helpful, and one that makes you want to do business with Capital Coil & Air.

You simply have to click here to request the program, and we will send you an email in response with an activation code and a link to download the program. Of course we are always here to assist you in any selections that you make, or to give you some engineering suggestions and recommendations. Thanks for giving us the opportunity to help you!

RELATED POSTS

10 THINGS THAT YOU DON’T KNOW ABOUT CAPITAL COIL & AIR

10 Things You Need to Know to Buy Replacement Coils Effectively

Repair or Replacement Coils?

CATEGORY SUCCESS

Stock Hot Water Coil – Quick Buyers Guide

Hot Water Coils

Depending on the specific project, selecting the appropriate Hot Water Coil can go one of two ways:  1) costly and complicated or 2) cheap and rather straight-forward. If you’re a representative or contractor reading this, you understand this fact all too well. And if you’ve dealt with us, you know that we much prefer going the second route rather than the first.  Considering the complexity of other types of coils, hot water coils should be as easy for to purchase and get delivered as they are for the manufacturer to build and keep in stock. So…why is it so hard to get your hot water coils shipped to where you need them when you need them?

Capital Coil & Air decided to create a quick buyers guide to when selecting and purchasing Stock Booster Coil Replacements :

  • First and foremost, you need to determine whether the booster coil needs to be 1 or 2 rows deep. Keep in mind that a 2 row booster coil will always generate substantially more BTU’s than a 1 row booster coil, but will also cause your air pressure drop to rise.
  • Generally speaking, booster coils are primarily installed someplace in the ductwork. If your duct size doesn’t match exactly with what we can build a good rule of thumb is to request your coils be built slightly larger than the ducts where they are going to be installed.
  • Booster coils are offered in sizes anywhere from 6” x 6” to 30” X 72”. Booster coils are 1 or 2 row coils that are available in 60 sizes.  Flanged or Slip & Drive casings are available on every size to meet your needs.
  • While most manufacturers claim they have “booster coils in stock”, and then ship in a week, we actually have (30) sizes in stock ready to ship the next day!

Whether you need (1) hot water coil or (200) hot water coils, Capital Coil & Air has the most competitive pricing in the business with the best lead times. Please see our Booster Coil Product Page. Most companies don’t want to bother with hot water coils.  No one does hot water coils better than Capital Coil & Air!